Linux之ipmitool管理BMC详解
作者:零时搞学习
BMC管理 – ipmitool
老规矩,先 help看看参数
[root@test ~]# ipmitool -h ipmitool version 1.8.18 usage: ipmitool [options...] <command> -h This help -V Show version information -v Verbose (can use multiple times) -c Display output in comma separated format -d N Specify a /dev/ipmiN device to use (default=0) -I intf Interface to use -H hostname Remote host name for LAN interface -p port Remote RMCP port [default=623] -U username Remote session username -f file Read remote session password from file -z size Change Size of Communication Channel (OEM) -S sdr Use local file for remote SDR cache -D tty:b[:s] Specify the serial device, baud rate to use and, optionally, specify that interface is the system one -4 Use only IPv4 -6 Use only IPv6 -a Prompt for remote password -Y Prompt for the Kg key for IPMIv2 authentication -e char Set SOL escape character -C ciphersuite Cipher suite to be used by lanplus interface -k key Use Kg key for IPMIv2 authentication -y hex_key Use hexadecimal-encoded Kg key for IPMIv2 authentication -L level Remote session privilege level [default=ADMINISTRATOR] Append a '+' to use name/privilege lookup in RAKP1 -A authtype Force use of auth type NONE, PASSWORD, MD2, MD5 or OEM -P password Remote session password -E Read password from IPMI_PASSWORD environment variable -K Read kgkey from IPMI_KGKEY environment variable -m address Set local IPMB address -b channel Set destination channel for bridged request -t address Bridge request to remote target address -B channel Set transit channel for bridged request (dual bridge) -T address Set transit address for bridge request (dual bridge) -l lun Set destination lun for raw commands -o oemtype Setup for OEM (use 'list' to see available OEM types) -O seloem Use file for OEM SEL event descriptions -N seconds Specify timeout for lan [default=2] / lanplus [default=1] interface -R retry Set the number of retries for lan/lanplus interface [default=4] Interfaces: open Linux OpenIPMI Interface [default] imb Intel IMB Interface lan IPMI v1.5 LAN Interface lanplus IPMI v2.0 RMCP+ LAN Interface serial-terminal Serial Interface, Terminal Mode serial-basic Serial Interface, Basic Mode usb IPMI USB Interface(OEM Interface for AMI Devices) Commands: raw Send a RAW IPMI request and print response i2c Send an I2C Master Write-Read command and print response spd Print SPD info from remote I2C device lan Configure LAN Channels chassis Get chassis status and set power state power Shortcut to chassis power commands event Send pre-defined events to MC mc Management Controller status and global enables sdr Print Sensor Data Repository entries and readings sensor Print detailed sensor information fru Print built-in FRU and scan SDR for FRU locators gendev Read/Write Device associated with Generic Device locators sdr sel Print System Event Log (SEL) pef Configure Platform Event Filtering (PEF) sol Configure and connect IPMIv2.0 Serial-over-LAN tsol Configure and connect with Tyan IPMIv1.5 Serial-over-LAN isol Configure IPMIv1.5 Serial-over-LAN user Configure Management Controller users channel Configure Management Controller channels session Print session information dcmi Data Center Management Interface nm Node Manager Interface sunoem OEM Commands for Sun servers kontronoem OEM Commands for Kontron devices picmg Run a PICMG/ATCA extended cmd fwum Update IPMC using Kontron OEM Firmware Update Manager firewall Configure Firmware Firewall delloem OEM Commands for Dell systems shell Launch interactive IPMI shell exec Run list of commands from file set Set runtime variable for shell and exec hpm Update HPM components using PICMG HPM.1 file ekanalyzer run FRU-Ekeying analyzer using FRU files ime Update Intel Manageability Engine Firmware vita Run a VITA 46.11 extended cmd lan6 Configure IPv6 LAN Channels
ipmitool命令的基本格式是:
ipmitool [选项] <命令> [参数]
其中:
选项
是一些可选的开关,用于设置ipmitool的一些参数。命令
是要执行的操作,如获取传感器信息等。参数
是可选的,它们是指定要执行的特定操作所需的选项和值。
常用的ipmitool命令
1.获取传感器信息
ipmitool sensor get <Sensor ID>
其中,
<Sensor ID>
是要获取的传感器的ID。
此命令将显示指定传感器的当前状态。
2.显示系统信息
ipmitool fru print
此命令将打印系统中所有可用的FRU(固件可重编程单元)信息。
3.电源控制
ipmitool power on 开启电源 ipmitool power off 关闭电源 ipmitool power reset 重置电源,按我的理解是没有完全断电的动作,类似系统的reboot ipmitool power cycle 先关闭电源,再开启
这些命令用于控制服务器的电源状态。
4.显示事件日志
ipmitool sel list
此命令将显示系统的事件日志。
5.启用/禁用BMC用户
ipmitool user enable <用户ID> ipmitool user disable <用户ID>
这些命令用于启用或禁用BMC用户。
以上是一些常用的ipmitool命令和它们的基本用法。
更多的ipmitool命令和选项可以通过ipmitool -h
命令查看完整的帮助文档。
关于OS下设定BMC或远程控制服务器的BMC命令等
ipmitool可以通过IPMI-over-LAN(基于LAN的IPMI协议)来远程控制BMC。
要使用IPMI-over-LAN,您需要确保BMC已经配置并连接到网络。
通过IPMI-over-LAN连接到BMC并进行远程控制的步骤
1.确定BMC的IP地址
使用ipmitool lan print
命令可以获取BMC的IP地址、MAC地址和子网掩码等信息。
如果BMC未配置IP地址,则需要在本地物理访问服务器以配置BMC。
2.连接到BMC
使用ipmitool lan set <参数>
命令设置BMC的用户名、密码和IP地址等信息。
例如,下面的命令设置BMC的IP地址为192.168.1.100,并将用户名设置为admin,密码设置为password:
ipmitool lan set 1 ipsrc static ipmitool lan set 1 ipaddr 192.168.1.100 ipmitool lan set 1 netmask 255.255.255.0 ipmitool lan set 1 defgw ipaddr 192.168.1.1 ipmitool user set name 2 admin ipmitool user set password 2 password
注意:
这里假设BMC使用的是默认的LAN通道1。
如果使用的是其他通道,则需要将1
替换为相应通道的数字。
3.启用IPMI-over-LAN功能
使用ipmitool channel info <通道号>
命令检查BMC所在通道的IPMI-over-LAN功能是否已经启用。
如果未启用,可以使用以下命令启用:
ipmitool channel setaccess <通道号> 2 ipmi=on auth=off link=on privilege=4
这将启用指定通道的IPMI-over-LAN功能,并使得通过此通道的IPMI会话的权限级别为4(ADMINISTRATOR级别)。
4.连接到远程BMC
使用以下命令连接到远程BMC:
ipmitool -H <BMC IP地址> -U <用户名> -P <密码> -I lanplus <命令>
注意,这里使用了-I lanplus
选项,以使用基于LAN的IPMI协议。
<命令>
是您要执行的ipmitool命令。
例如:
要获取传感器信息,可以使用以下命令:
ipmitool -H 192.168.1.100 -U admin -P password -I lanplus sensor list
这将显示远程BMC的传感器列表信息。
总结
以上是通过ipmitool进行远程BMC控制的基本步骤。
请注意,远程BMC的访问权限应该是受限的,只有授权用户才能访问。此外,您还应该确保网络安全措施已经得到了应用,以确保远程访问的安全性。
这些仅为个人经验,希望能给大家一个参考,也希望大家多多支持脚本之家。